University of Cambridge > Talks.cam > Isaac Newton Institute Seminar Series > C5 - Coherent interferometric imaging in random media III

C5 - Coherent interferometric imaging in random media III

Add to your list(s) Download to your calendar using vCal

If you have a question about this talk, please contact Mustapha Amrani.

Inverse Problems

I will describe the the mathematical problem of imaging remote sources or reflectors in heterogeneous (cluttered) media with passive and active arrays of sensors. Because the inhomogeneities in the medium are not known, and they cannot be estimated in detail from the data gathered at the array, we model the uncertainty about the clutter with spatial random perturbations of the wave speed. The goal of the lectures is to carry out analytically a comparative study of the resolution and signal-to-noise ratio (SNR) of two array imaging methods: the widely used Kirchhoff migration (KM) and coherent interferometry (CINT). By noise in the images we mean fluctuations that are due to the random medium.

Kirchhoff migration [2, 3] and its variants are widely used in seismic inversion, radar [10] and elsewhere. It forms images by superposing the wave fields received at the array, delayed by the travel times from the array sensors to the imaging points. KM works well in smooth and known media, where there is no wave scattering and the travel times can be estimated accurately. It also works well with data that has additive, uncorrelated measurement noise, provided the array is large, because the noise is averaged out by the summation over the many sensors, as expected from the law of large numbers. KM images in heterogeneous (cluttered) media are unreliable and difficult to interpret because of the significant wave distortion by the inhomogeneities. The distortion is very different from additive, uncorrelated noise, and it cannot be reduced by simply summing over the sensors in the array. CINT images efficiently in clutter [5, 6, 7], at ranges that do not exceed one or two transport mean free paths [11]. Beyond such ranges the problem becomes much more difficult, specially in the case of active arrays, because the clutter backscatter overwhelms the echoes from the reflectors thatwe wish to image. Coherent imaging in such media may work only after pre-processing the data with filters of clutter backscatter, as is done in [9, 1].

The CINT method has been introduced in [5, 6, 7] for mitigating wave distortion effects induced by clutter. It forms images by superposing time delayed, local cross-correlations of the wave fields received at the array. Here local cross correlations means that they are computed in appropriate time windows and over limited array sensor offsets. It has been shown with analysis and verified with numerical simulations [5, 6, 7, 8, 4] that the time and offset thresholding in the computation of the cross-correlations is essential in CINT , because it introduces a smoothing that is necessary to achieve statistical stability, at the expense of some loss in resolution. By statistical stability we mean negligibly small fluctuations in the CINT image even when cumulative fluctuation effects in the random medium are not small. The lectures will give a detailed comparative study between KM and CINT in som scattering regimes wh

This talk is part of the Isaac Newton Institute Seminar Series series.

Tell a friend about this talk:

This talk is included in these lists:

Note that ex-directory lists are not shown.

 

© 2006-2024 Talks.cam, University of Cambridge. Contact Us | Help and Documentation | Privacy and Publicity