University of Cambridge > Talks.cam > Physics and Chemistry of Solids Group > Scanning helium microscopy (SHeM): Real space imaging of delicate surfaces

Scanning helium microscopy (SHeM): Real space imaging of delicate surfaces

Add to your list(s) Download to your calendar using vCal

If you have a question about this talk, please contact Stephen Walley.

Microscopy has been a major enabling technique for the development and understanding of materials from the bottom up. Some of the major insights in the development of modern materials have come from scanning probe, electron and ion microscopies, with advances in resolution and sensitivity enabling new material science. Unfortunately charged beam techniques tend to cause surface damage and scanning probe techniques are limited to relatively flat surfaces and suffer from limited scan speeds. In the current work I present recent advances in the development of neutral beam microscopy. In collaboration with colleagues at the University of Newcastle, NSW , we have recently published some of the first reflective mode images measured with a neutral helium beam [1]. A major benefit for the technique is the very low beam energy ( 1 the SHeM aims to deliver uniquely surface sensitive images with atomic resolution, while causing no surface damage. Helium microscopy is suitable for measuring a variety of samples including insulator, semiconductor, explosive, biological and 3D self-assembled materials and being a real space technique will not involve complicated post processing techniques. Atom microscopy has been in development for some years internationally. Many of the technological barriers, for example helium focusing, sample preparation and nanoscale manipulation have now been addressed to enable preliminary instruments to be developed[1,2], however detection of neutral beams remains a challenge, particularly for helium given its high ionisation energy3. Applications that require time sensitive measurements require a small ionisation volume; however, when high temporal resolution is not required, ionisers having a much larger volume are possible. We describe a detector developed on the basis of recent successful results7 applied to surface spin-echo experiments[4,5,6] and having a sensitivity of 0.83A/mbar, the highest yet reported for helium atoms. Finally I discuss some very recent results showing that there is evidence for contrast mechanisms other than topographical in origin and discuss various alternative proposals, and possible applications of the technique.

[1] D.J. Ward et al. Nucl. Instr. Meth. Phys. Res B 340 76-80, 2014. [2] H. Pauly “Atom, molecule and cluster beams”; Springer: Berlin, (2000). [3] P. Witham and E. Sánchez, Rev. Sci. Inst. 82(10), 103705, 2011. [4] D.J. Ward et al. Phys Rev Lett. 105, 136101, 2010 [5] E.M. McIntosh et al. Phys. Rev. Lett. 110, 086103, 2013. [6] Lechner, B.A.J., et al. Angew. Chemie – Int. Ed., 52 (19), pp. 5085‐5088, 2013. [7] A. Alderwick et al. Rev. Sci. Instrum. 79, 123301, 2008.

This talk is part of the Physics and Chemistry of Solids Group series.

Tell a friend about this talk:

This talk is included in these lists:

Note that ex-directory lists are not shown.

 

© 2006-2024 Talks.cam, University of Cambridge. Contact Us | Help and Documentation | Privacy and Publicity